1. With 8 20A relay output units; 2. Each loop can be switched manually; 3. With LED lights to display the switch status of each circuit; 4. Each circuit can set relay closing delay and relay interval protection time; 5. Each loop is equipped with current detection to protect the load
Learn more1. With 4 10A relay output units; 2. Each loop can be switched manually; 3. With LED lights to display the switch status of each circuit; 4. Each loop can set the relay closing delay and relay interval protection time.
Learn more1. With 4 10A relay output units; 2. Each loop can be switched manually; 3. With LED lights to display the switch status of each circuit; 4. Each loop can set the relay closing delay and relay interval protection time.
Learn more1. With 4 5A relay output units; 2. Each loop can be switched manually; 3. With LED lights to display the switch status of each circuit; 4. Each loop can set the relay closing delay and relay interval protection time.
Learn more1. Real-time monitoring of input voltage, current, active power, apparent power, real-time power and other parameters; 2. The current transformer is connected externally, and the user can choose the current of the transformer according to the actual use; 3. It can cooperate with the smart gateway to use input voltage, current, power and other parameters as logic trigger conditions to perform corresponding actions, such as large current alarms, alarms when power consumption exceeds a predetermined value, etc.; 4. All electricity consumption data is stored in the cloud and supports APP real-time query and other functions.
Learn more1. Data communication between external RS232 equipment and AiᅠBus can be realized; 2. Data communication between external RS485 and Ai Bus can be realized.
Learn more1. With short-circuit and over-current protection; 2. Load status indication; 3. System reset function; 4. The ripple is less than 150mV.
Learn more1. Data communication between RJ45 and EBS Bus can be realized; 2. It can synchronize the clock of the cloud server and the clock of the LAN NTP server; 3. With automation function, it can realize various automatic functions such as time condition and equipment condition trigger; 3.1. Time conditions: timing, time period, every day/weekend/custom week, etc.; 3.2. Equipment conditions: human body induction, temperature changes, dry contact switches, button actions and other equipment status triggers; 4. It can provide clock for EBS Bus equipment.
Learn more1. With short circuit and over current protection; 2. With load status indication; 3. With system reset function; 4. The ripple is less than 150mV; 5. Comply with EMC/safety standards.
Learn more1. The air conditioner can be set to on and off mode; 2. The wind speed of the air conditioner can be set: high wind, medium wind, low wind; 3. Air conditioning modes can be set: cooling, heating, dehumidification, ventilation; 4. Temperature can be monitored, with 18B20 temperature probe externally; 5. DC0-10V output, the wind speed can be controlled.
Learn more